defr Glossar

Equal velocity in sample taking of a gas for dust measurement.

To obtain a representative sample independent of particle size, it is necessary to remove the sample stream isokinetically, i.e. with the same velocity as the main stream. The following Figure shows the pattern of the flow lines in the vicinity of a thin-walled sampling probe, with w the velocity of the main stream and v the velocity of the sample stream:

Sampling of gas with dust particles
Fig. 25: Sampling of gas with dust particles

In the isokinetic case (w=v, Fig. 25), all particles flowing toward the intake opening are equally collected. If the sample taking velocity is too low (w>v), heavy particles can enter the probe even if the flow line on which they were located passes by the probe. Thus too many large particles are collected. If the sample taking velocity is too high (w<v), heavy particles fail to adhere to the flow lines and end up bypassing the probe. So too few large particles are collected. Isokinetic sampling is often susceptible to faults since the sampling can easily be a super- or sub-isokinetic sampling. The resulting measurement error is significantly higher in case of sub-isokinetic sampling (w>v). In SIGRIST dust measurements, the diameter of the sampling is adjusted to the velocity of the main stream such that a super-isokinetic sampling (w<v) results. The resulting measurement error is small as long as the particle size distribution of the dust particles is constant.

Index

Contact distribution partner

{{selectedCountry.Name}} {{country.Name}}

Please select your businessarea

{{ba.Name}}

Please select

{{area.Name}}

Please select your businessarea

{{ba.Name}}
{{selectedCountry.Name}} {{country.Name}}
{{vm.getBusinessAreaStringByVendor(vendor)}} {{area.Name}}
{{vm.getBusinessAreaStringByVendor(vendor)}}
Leonardo Pio
Responsible for applications: Water, beverages & food, industrial processes for the cantons: AG, BE-DE, BL, BS, LU, NW, OW, TI, UR, SO, TI, VS-DE & ZG
Jacques Savary
Responsible for applications: Water, Beverages & Food, Industrial Processes for the cantons: BE-FR, FR, GE, JU, NE, VD & VS-FR
Vakant
Responsible for applications: Water, Beverages & Food, Industrial Processes for the cantons: BE-FR, FR, GE, JU, NE, VD & VS-FR
Ihr Businesspartner für Getränke & Lebensmittel:
Für Wasser, Industrielle Prozesse, Verkehr & Umwelt kontaktieren Sie unseren Hauptsitz.

Your distribution partner for beverages & food:
For water, industrial processes, traffic & environment please contact our headquarters

Ihr Businesspartner für Getränke & Lebensmittel:
Für Wasser, Industrielle Prozesse, Verkehr & Umwelt kontaktieren Sie unseren Hauptsitz.

Your distribution partner for beverages & food:
For water, industrial processes, traffic & environment please contact our headquarters

Contact headquarters

Ralf Isenberg
Sales Manager ScrubberGuard
Öffnungszeiten:
Montag–Freitag 08:00–12:00 und 13:30–17:00
Feiertage & Betriebsferien:
Seppitag: 19. März 2026, Ostern: 03. – 06. April 2026, Auffahrt: 14. Mai 2026, Pfingstmontag: 25. Mai 2026, Fronleichnam: 4. Juni 2026, Bundesfeiertag: 01. August 2026, Maria Himmelfahrt: 15. August 2026, Allerheiligen: 01. November 2026, Maria Empfängnis: 08. Dezember 2026, Betriebsferien: 24. Dezember 2026 – 03. Januar 2027
Opening hours:
Monday–Friday 08:00am–12:00pm und 1:30pm–5:00pm
Public & company holidays:
St Joseph's Day: 19 March 2026, Easter: 03 – 06 April 2026, Ascension Day: 14 May 2026, Whit Monday: 25 May 2026, Corpus Christi: 4 June 2026, Federal Holiday: 01 August 2026, Assumption Day: 15 August 2026, All Saints Day: 01 November 2026, Conception of Mary: 08 December 2026, Company holidays: 24 December 2026 – 03 January 2027